中文

  • Home
  • About UsOverview | Mission & Vision | Our Customers | Business Partners | Approvals & Certifications | Milestones
  • ProductsProduct Categories | Business Solutions | Addison & Your Business | Ordering & Testing Information | Warranty
  • Download Product Catalogue | Online Document Viewing
  • Technical Lib Cable Related Standards | Cable Testing & Fire Resistant Cable | Cabling System Library | Material Properties | Cable Glossary
  • Contact
  • Enquiry
  • Sitemap
  • Links Testing Authorities | Testing Equipment Manufacturers | Cable Magazines | Cable Organizations | Addison Corporater Website
  • Airport Cables
  • Alarm & Audio Cables
  • Aluminium Conductor Cables
  • Automotive Cables
  • Belden Equivalent Cables
  • Bus Cables
  • BS standard Cables
    • BS 5308
    • BS 5467
    • BS 6346
    • BS 6724
    • BS 7211
    • BS 8573
  • Coaxial Cables
  • Cable Glands
  • Cables for Oil Industry
  • Control Cables
  • Composite Cables
  • Data Cable
  • Elevator Cables
  • Fiber Optic Cables
  • Fire Resisting Cables
    • Fire Resisting Cable
    • LSZH Flame Retardant Cable
    • PVC Flame Retardant Cable
  • Flexible Cables
  • Heat Detection Cables
  • High Temperature Cables
  • Highway Cables
  • IEC 60502-1
  • Industrial Cables
    • American (UL) Standard
    • Australian Standard (LV)
    • Australian Standard (MV)
    • British Standard
    • French Standard
    • German Standard
    • Harmonized Code
    • Itanlian Standard
    • JIS Standard
    • Spanish Standard
    • Portuguese Standard
  • Instrumentation Cables
  • Lan Cables
  • Offshore Cables
    • NEK606
    • BS6883 & BS7917
    • UKOOA
    • IEC60092
    • JIS
    • Marine & Gas Cables
  • Power Cables
    • Low Voltage Cables
    • Medium Voltage Cables
    • High Voltage Cables
  • Military Cables
  • Mining Cables
  • Motor Connecting Cables
  • Photovoltaic Cables
  • Railway Cables
  • Rolling Stock Cables
  • Robotics
  • Rubber & Crane Cables
  • Security Cables
  • Special Cables
  • Spiral Cables
  • Telephone Cables
  • Thermocouple Cables
  • Windmill Cables
  Fire Retardant Cables 
Fire Retardant Power & Control Cables
Fire Retardant Instrumention Cables
Fire Retardant RS485 Databus Cables
Fire Retardant Data Cables
Fire Retardant Coaxial Cables
Fire Retardant Fiber Optic Cables

600/1000V XLPE Insulated, LSZH Sheathed, Armoured Cables to IEC 60502-1 (Single Core) 

FTX300 1RZ1MZ1-R (CU/XLPE/LSZH/AWA/LSZH 600/1000V Class 2)

APPLICATION 

The cables are mainly used in power stations, mass transit underground passenger systems, airports, petrochemical plants, hotels, hospitals, and high-rise buildings.

STANDARDS

Basic design adapted to IEC 60502-1 

FIRE PERFORMANCE

Flame Retardance (Single Vertical Wire Test)

EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); 

CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*

Reduced Fire Propagation   (Vertically-mounted bundled wires & cable test)

EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4

Halogen Free

IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; 

CEI 20-37/2-1 ; BS 6425-1*

No Corrosive Gas Emission

IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; 

CEI 20-37/2-2 ; BS 6425-2*

Minimum Smoke Emission

IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; 

CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*

No Toxic gases

NES 02-713; NF C 20-454

Note: Asterisk * denotes superseded standard.

VOLTAGE RATING

600/1000V

CABLE CONSTRUCTION

Conductor: Plain annealed copper wire, stranded according to IEC 60228 class 2.

Insulation: Extruded cross-linked XLPE compound.

Inner sheath: LSZH Compound

Armouring: Aluminium Wire

Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option.

COLOUR CODE

Insulation Colour as per BS7671

With Earth Conductor

Without Earth Conductor

2Cores

-

Brown, Blue

3Cores

Yellow/Green, Brown, Blue

Brown, Gray, Black

4Cores

Yellow/Green, Brown, Gray, Black

Brown, Gray, Black, Blue

5Cores

Yellow/Green, Brown, Gray, Black, Blue

Brown, Gray, Black, Blue, Black

Above 5 Cores

Yellow/Green, Black Numbered

Black Numbered

Sheath Colour: Black (other colors upon request)

Physical AND THERMAL PROPERTIES

Temperature Range During Operation: -30°C – +90°C
Temperature Range During Installation: -5°C – +50°C

Minimum Bending Radius: 10 x Overall Diameter

Electrical PROPERTIES

Dielectric test:

3500 V r.m.s. x 5’ (core/core)

Insulation resistance

≥1000 MΩ x km (at 20°C)

Short circuit temperature  

250°C

CONSTRUCTION PARAMETERS

Conductor

FTX300 1RZ1MZ1-R

No. of Core X

Cross Section

No./Nominal

Diameter of

Strands

Diameter 

Under 

Armour

Armour 

Wire 

Diameter  

Nominal

Overall 

Diameter

Approx. 

Weight

 mm2

No./mm

mm

mm

mm

kg/km 

1x70

19/2.14

15.4

1.25

21.5

960

1x95

19/2.52

17.3

1.25

23.4

1240

1x120

37/2.03

19.1

1.6

25.9

1650

1x150

37/2.25

21.1

1.6

27.9

1970

1x185

37/2.52

23.2

1.6

30.1

2390

1x240

61/2.25

26.2

1.6

33.2

3040

1x300

61/2.52

28.8

1.6

35.8

3790

1x400

61/2.85

32.7

2.0

40.9

4790

1x500

61/3.20

36.2

2.0

44.6

5880

1x630

127/2.52

40.6

2.0

49.2

7400

1x800

127/2.85

45.7

2.5

55.7

9500

1x1000

127/3.20

50.6

2.5

61.0

11750

Electrical PROPERTIES

Conductor Operating Temperature : 90°C

Ambient Temperature : 30°C

Current-Carrying Capacities (Amp)

Conductor cross-sectional
area

Reference Method 1 (clipped

direct)

Reference Method 11

 (on a perforated horizontal cable 

tray or Reference Method 

13 [free air] )

Reference

Method 12

(free air)

In single-way ducts

Laid direct in ground

 

2

cables, single-phase 

a.c. or

 d.c.

3 or 4

cables,

3-phase

 a.c.

2

cables, single-phase 

a.c. or

 d.c.

3 or 4

cables,

3-phase

 a.c.

3 cables

3-phase

a.c. trefoil

touching

2

cables, single-phase 

a.c. or

 d.c.

3 or 4

cables,

3-phase

 a.c.

2

cables, single-phase 

a.c. or

 d.c.

3 or 4

cables,

3-phase

 a.c.

1

2

3

4

5

6

7

8

9

10

mm2

A

A

A

A

A

A

A

A

A

70

303

277

322

293

285

310

280

340

290

95

367

333

389

352

346

365

330

405

345

120

425

383

449 

405

402

410

370

460 

389

150

488

437

516

462 

463 

445

405

510

435

185 

557

496

587

524

529

485

440

580

490

240 

656

579

689

612

625

550

500

670

560

300 

755

662

792

700

720

610

550

750

630

400 

853

717

899

767

815

640

580

830

700

500 

962

791

1016

851

918

690

620

910

770

630 

1082

861

1146

935

1027

750

670

1000

840

800 

1170

904

1246

987

1119

828

735

1117

931

1000 

1261

961

1345

1055

1214

919

811

1254

1038

Voltage Drop (Per Amp Per Meter)

Conductor 
cross-sectional 

area

2 cables
d.c.

2 cables single-phase a.c.

3 or 4 cables three-phase a.c.

2 cables singlephase
a.c.

3 or 4 cables,
3-phase a.c.
touching

Reference Method 1 &
11 (touching)

Reference Method 1, 11
& 12 (in trefoil touching)

Reference Method 1 & 11
(Flat touching)

In
ducts

In
ground

In
ducts

In
ground

1

2

3

4

5

6

7

8

9

mm2

mV/A/m

mV/A/m

mV/A/m

mV/A/m

mV/A/m

mV/A/m

mV/A/m

mV/A/m

 

 

r

x

z

r

x

z

r

x

z

 

 

 

 

70 

0.67

0.68

0.20

0.71

0.59

0.17

0.62

0.6

0.25

0.65

0.80

0.70

0.70

0.61

95 

0.49

0.51

0.195

0.55

0.44

0.17 

0.47

0.46

0.24

0.52

0.65

0.53 

0.56

0.46

120 

0.39

0.41

0.190

0.45

0.35 

0.165

0.39

0.38

0.24

0.44

0.55

0.43 

0.48

0.37

150 

0.31

0.33

0.185

0.38

0.29

0.160

0.33

0.31

0.23 

0.39 

0.50

0.37 

0.43 

0.32

185 

0.25

0.27

0.185

0.33

0.23

0.160

0.28

0.26

0.23

0.34

0.45

0.31

0.39

0.27

240 

0.195

0.21

0.180

0.28

0.18 

0.155

0.24

0.21 

0.22

0.30

0.40 

0.26

0.35

0.23

300 

0.155

0.17

0.175

0.25

0.145

0.150

0.21

0.17

0.22

0.28

0.37 

0.24

0.32

0.21

400 

0.115

0.145

0.170

0.22 

0.125

0.150

0.195

0.160 

0.21

0.27

0.35

0.21

0.30

0.19

500 

0.093

0.125 

0.170

0.21

0.105

0.145

0.180

0.145

0.20

0.25

0.33

0.20

0.28

0.18

630 

0.073

0.105

0.165

0.195

0.092

0.145

0.170

0.135

0.195

0.24

0.30

0.19

0.26

0.17

800 

0.056

0.090

0.160

0.190

0.086 

0.140

0.165

0.130

0.180

0.23

0.28

0.18

0.24 

0.16

1000 

0.045 

0.092

0.155

0.180

0.080

0.135

0.155

0.125

0.170

0.21

0.26

0.17 

0.22

0.15

Note :
r = conductor resistance at operating temperature
x = reactance
z = impedance

 

 

E-mail: uk@addison-cables.com

 

Addison

Marchants Industrial Centre, Mill Lane Laughton, 
Lewes, East Sussex, BN8 6AJ, UK

Tel: 44-207-4195087

Fax: 44-207-8319489

Email: sales@addison-cables.com